Scored
Your Name
Journal Entry For
Module 7 - Building Envelope Systems
ACC Revit File Link
Created
Feb 14, 2024 11:14 AM
Last Edited
Feb 15, 2024 1:11 AM
Created by
S
Sam GarciaPlease enter Your Name to link to your Design Journal, and paste a link to your personal folder on ACC in the ACC Folder Link field above.
For 2 Units
Wall Surfaces
- Exterior wall surfaces currently rely on brick on metal stud layer. I selected this material due to:
- Visual appeal of brick
- Bricks are widely used and available, which has positive cost implications
- Relatively high thermal resistance value (R value of 54.02 per Revit)
- Relatively low heat transfer coefficient (0.0185 per Revit)
- The characteristics described above are beneficial given Sao Paolo’s relatively warm climate.
Roof Surfaces
- “Two part roof” relies on a flat portion combined with a north-facing sloped portion.
- Solar PV will be pased on north-facing sloped portion to maximize onsite solar generation
- Considering implementing green roof on flat portion
Openings / Glazed Surfaces
- North facing wall relies entirely on curtain wall fitted with double glazing - 1/4 in thick / bluegreen low-E glass
- The north-facing curtain walls represent most important opportunity for thermal efficiency of windows given disproportionate sun access
- Non north-facing walls will rely on less efficient glass type to enable cost reductions
- Roof features skylight with the same glass used on north facing walls - double glazing - 1/4 in thick / bluegreen low-E glass
Shading / Sun Control
- North facing roof edge features 10’ overhang
- Other roof edges feature 4’ overhangs
- North facing curtain wall incorporates light shelves at each floor level