Design Journal Entry - Module 11

Scored
Your Name
Journal Entry For
Module 11 - Power & Lighting Systems
ACC Folder Link
ACC Revit File Link
Created
Mar 12, 2025 4:40 AM
Last Edited
Mar 12, 2025 11:38 AM
Created by
R
Ryan
Files & media
Pinterest link

Text

https://pin.it/7idDoFsqa
image

Power System Elements

Since the spaces excluded utility rooms and restrooms, power was supplied by two wall-mounted power panels to four admin offices and an open office. The two western rooms are served by a 208V MCB 225A panel to 12 duplex receptacles while the three western rooms are supplied power from a 208V MCB 400A panel to 23 duplex receptacles.

image

Lighting System Elements

The four offices feature 60W-120V sconces on opaque walls and 150-120V hemispheric pendant lights. The larger open office has 1x4 120V linear box ceiling lights and 60W-120V floor lamps. Each office has a single switch to control all lights while the open office has two.

image