Practice Exercise - Building Envelope

Test Case 1: Building Envelope Choices

image

I was not able to achieve the predicted mean EUI based on just building envelope choices alone. In order to get this number, my recommended settings include:

  • Rotating 90 degrees
  • 0% Southern WWR
  • 2/3 Southern Window Shades
  • Southern Double paned glass
  • 0% Northern WWR
  • 2/3 Northern Window Shades
  • Northern Double paned glass
  • 0% Western WWR
  • 2/3 Western Window Shades
  • Western double paned glass
  • 0% Eastern WWR
  • 2/3 Eastern Window Shades
  • Eastern double paned glass
  • Wall Construction - R38 wood
  • Roof Construction - R60
  • Infiltration - 0.17 ACH

Test Case 2: Building Envelope & Power + Lighting Choices

image

This puts us below the 54 kBTU/ft2/yr. My recommended settings include:

  • Same as above
  • Lighting Efficiency - 0.3 W/SF
  • Adding occupancy controls
  • Plug load efficiency - 0.6 W/SF
  • HVAC - ASHRAE package terminal heat pump
  • Operating schedule: 12/5

Test Case 3: Building Envelope, Power & Lighting Choices, & PV Panels

image

And now we are finally in the green! My recommended settings include:

  • All of the above
  • 20.4% panel efficiency
  • 30 year payback limit
  • 90% surface coverage

Overall, I would really play around with HVAC, PV, and lighting/power so that I can enhance the building envelope because I feel that those did very small in comparison to effecting the EUI.