- Plumbing floor plan (1st floor plan)
- Overview of the whole plumbing system
Section of the system
Interior view
Axo view
The only problem I have encountered is when trying to connect the sewer system, the pipe will not be automatically generated and connected with the main sewer. Hence, I need to adjust the middle elevation to 1 foot to make it works
When mirroring the north restroom, it is better to mirror the main piping and the vertical pipes first, then try to connect with the plumbing fixtures later