Module 7

Scored
Your Name
🏠Vargas, Alonso
Journal Entry For
Module 7 - Building Envelope Systems
ACC Folder Link
https://acc.autodesk.com/docs/files/projects/cbef7261-4ed5-4dad-99c1-e2a751c74519?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.ebbVg4JkS4aDbB73eyWeqQ&viewModel=detail&moduleId=folders
ACC Revit File Link
https://acc.autodesk.com/docs/files/projects/cbef7261-4ed5-4dad-99c1-e2a751c74519?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.ebbVg4JkS4aDbB73eyWeqQ&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3AUtANA2YUQ1SRw-lL1FXJGQ&viewModel=detail&moduleId=folders
Created
Jan 6, 2025 12:33 AM
Last Edited
Jan 6, 2025 12:33 AM
Created by
Glenn Katz

Model

image

Energy Model Creation

image

Baseline

image

South Facing Window - Adjustment

image

North Facing Window - Adjustment

image

West Facing Window - Adjustment

image

East Facing Window - Adjustment

image

Fixture Efficiency- Adjustment

image

Renewable

image

Key Factor Tile

image

Optimization

image

Comparison

Initial

88 kWh / m2 / year (Machine Learning from Forma)

Initial Design - Insight

288 kWh / m2 / year

After Design - Optimization

152 kWh / m2 / year

Next Time Improve….

Adjustments

  • Roof is now flat.
  • Changes roof to increase R value.
  • Reduce Window to Wall Ratio to at least 0.35

Thermal Properties - Envelope

  • Type: Walls
  • Description: Concrete Masonry Units (CMU) cavity wall on exterior and Gypsum Wall Board (GWB) on furring on interior, Exterior Function
  • Thermal Resistance (R): 4.5 (m2K)/W (R-25 Imperial)

Wall Assembly

image
  • Type: Roof
  • Description: Steel Deck with Metal Deck and Insulation and Ethylene Propylene Diene Monomer (EPDM) Finish
  • Thermal Resistance (R): 19.61 (m2K)/W (R-111 Imperial)
image

Window to Wall Ratio Calculation - Schedules

Calculation = 491 m2 / (491 m2 + 988 m2) = 0.33

Windows - 491 m2

image

Walls - 988 m2

image

Re-do Energy Analysis

image

Baseline

image

Operating Schedule

image

Final

Comparison

Initial

88 kWh / m2 / year (Machine Learning from Forma)

Initial Design - Insight

222 kWh / m2 / year

image

After Design - Optimization

57.6 kWh / m2 / year

image

Adjustment - PV Surface to 0% in Insight

Comparison

Initial - Forma

88 kWh / m2 / year (Machine Learning from Forma)

Adjustment - Insight - NO PV (DEMAND)

113 kWh / m2 / year =* 2,897 m2 = 327,361 kWh / year

After Design - Optimization (SUPPLY)

175,808  kWh / year (54% of demand)

  • 18.6% Efficiency Coverage
  • 50 year payback limit
  • 100% of surface area

DIFFERENCE = 327,361 kWh / year - 175,808  kWh / year  = 151,223 kWh / year

image
image