Example - Radiant Floor System

Note: The water heater, expansion tank, and valves could be located in a remote location — in a basement or mechanical room.
You can download this file here:
AI Prompts
Creating a Radiant Floor System
Prompt | Tool Options
🟢 = Autodesk Asst
🔵 = Revit MCP
🟣 = Python + Dynamo |
Add a hot water radiant floor system to this residential apartment unit.
In-Floor Tubing:
• Provide three zones with thermostats in each room:
◦ Living Area
◦ Bedroom Area
◦ Bathroom
Hot Water Source:
• Route the tubing to a water heater in a mechanical room out of view. | 🟣 |
Claude Response
I'll check the open Revit model to see the apartment layout before laying out the radiant zones.
Layout checks out (no tube crossings, ~555 ft of tubing across three counterflow loops). Now building the pipe types and positioning equipment in the mechanical closet.
All 92 pipe runs and fittings connected cleanly. Now the thermostats and making the in-slab tubing visible on the mechanical plan.
The radiant floor system is in the model, on the L1 - Mechanical plan. All 184 pipe connectors are joined with none left open, and the three zones are color-coded: red for Living, blue for Bedroom, green for Bathroom.
Hot water source. The heat source is a hydronic water heater (WH-1). It sits in the small enclosed room behind the walk-in closet, which you reach through the 30" pocket door, so it's out of view. That room also holds:
- the circulator (P-1)
- a 2-gallon expansion tank (ET-1)
- ¾" copper supply and return manifolds, with one branch per zone
In-floor tubing. Each zone is a ½" PEX loop in a counterflow spiral, about 1½" below finished floor:
Zone | Thermostat | Spacing | Tubing |
RF-1 Living Area | T-1, east face of the bedroom/living partition | 12" o.c. | ~280 ft |
RF-2 Bedroom Area | T-2, west face of the same wall | 12" o.c. | ~235 ft |
RF-3 Bathroom | T-3, bathroom east wall | 6" o.c. | ~45 ft |
- Bathroom tubing stays clear of the shower, WC and vanity.
- Leaders run in the slab from the mechanical room, through the walk-in closet, to each zone, and none of them cross.
- Thermostats are at 5'-0" AFF.
- Tagging: every pipe and fitting carries its zone name in Comments, which is what drives the view filters.
Model housekeeping:
- I added two pipe types, "PEX - Radiant Tubing" and "Hydronic - Copper".
- The view range on the L1 Mechanical and Plumbing plans now reaches 6" below the level, so the in-slab tubing shows.
- The model is not saved, so you can review it before committing.
Not modeled:
- Zone control: there were no zone valve or zone controller families loaded, so the thermostats aren't wired to anything in the model. You'll need either zone valves on each supply branch or one circulator per zone.
- Mixing valve: I'd add a thermostatic mixing valve after the heater, because radiant slabs want about 100–120°F water.
- Equipment sizes: the circulator and heater are generic library types. Size them to the actual heat load.