Module 4 Template

Link to Student
Submitted For
Module 4 - Skin and Bones

Working link to your Revit cloud model in Forma Data Management.

https://acc.autodesk.com/docs/files/projects/feb2c753-99e4-4d4f-a687-16d14415d5d3?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.y5Y8H7MORQi3cQmNcjZrug&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3A9vZn6j31Sz2aqSXQdq4FhA&viewModel=detail&moduleId=folders

Working link to your Individual Forma Board

https://app.autodeskforma.com/board/up_nj1olkuzcf/board_b4bc5d37-d370-49f3-8ec7-fa6d73a50c56?x=-16893.318176173132&y=-9390.159056950308&w=49919.58250993203&h=24569.794516607173

image

DF sheet set at D size, 30 by 42 inches, six sheets. Delete any blank sheets.

Miaoying Li Building.pdf4.6 MiB

Screenshot of your Insight result alongside your Week 3 Forma result.

image
image
image
image

Design memo of 300 to 400 words: what survived the handoff, what you rebuilt, what assembly choices you made and why, and where Revit and Forma disagreed.

For the hand off I did not change the amount of levels I had or the square footage. I did change the orientation of my building in Forma before the hand off happened in revit. I just could not sleep with the fact that a whole side to my building had little daylight exposure. After admiring my rendering I noticed that the AI flipped my building and rotated it because I had given it the back of my building to look at. Now that I realized the rotation fixes a few problems and that the courtyard was supposed to be an accessible community space, also that the commercial level is on the first floor. I decided to rotate the orientation of my building to have the courtyard face the outside. Most things from my hand off survived since I was satisfied with how my buildings looked overall. However, I had to change all my stairs and rebuild them in revit which took a long time. I also rebuilt some floors since they disappeared when I uploaded them to revit for some reason, and finally I rebuilt the walls with the correct r-value assemblies.

For both my buildings I had the same wall assemblies where the bottom floor had the commercial assembly/ podium assembly and the upper floors had a residential assembly. My podium assembly consists of a brick outer layer, an air barrier, a glass batt insulation and then the CMU. My residential assemblies consisted of a fiber cement outer finish, an air barrier, glass batt insulation, a vapor barrier, plywood sheathing, and metal stud layer in between. I did the metal studs because my building is taller than 5 stories, it is actually a 5 story building and also an 8 story building so I decided to build it out of steel. For my green roof, I found an assembly online and found materials in Revit that best matched what the online assembly displayed. For example, for vegetation I used grass, for soil I used earth, and for insulation I used rigid exterior insulation, and for the concrete I used cast in-place concrete etc. I changed all my window glazings on the south facing side (mostly) since my building was at an angle to a lower emissivity glazing and the other windows although were still double glazed had a higher emissivity rate.

Finally, Revit and Forma disagreed when it came to my stairs, it was very prevalent that my stairs were not aligned when I went from a taller podium level to the second floor which was shorter. And I also did not have elevator shafts that were imported.