Module 6 Template

Link to Student
Submitted For
Module 6 - Load Bearing

Working links to both Arch and Stru models in Forma Data Management.

Architecture Model

Structural Model

Working link to your Individual Forma Board

https://app.autodeskforma.com/board/up_tynup9cnpz/board_43ed2f19-6170-49d5-8dea-cf495ab456c4

PDF sheet set of Structural Plans, 30 by 42 inches (E1 size)

CEE 120A Module 6 Sheet Set.pdf254.7 KiB

Classified clash report with counts.

Module 6 Clash Issue Report.pdf3.5 MiB

Design memo of 300 to 400 words: which system and why, where the grid fought your architecture, what you changed in the architectural model.

For the structural system, I chose concrete framing and slabs for the first commercial floor and heavy timber framing for the six residential floors above. The concrete is a strong and durable base structure that can efficiently support the loads from the residential levels while also accommodating the larger open spaces required at ground level. The upper floors use a heavy timber system consisting of timber columns, beams, and open-web wood joists. Using wood reduces the overall building carbon footprint and weight compared to a fully concrete structure. The timber column layout was spaced independently from the first-floor grid to better fit the residential floorplans.

One of the main challenges was coordinating the structural grid with the architectural design. My first few grid layouts had column lines in the hallways, which is less than ideal. I adjusted the column spacing and layout to avoid the hallways, but I missed another key element: avoiding placing columns too close to stairwells.

When I uploaded the architectural and structural models into Forma, 1,230 clashes came up. Most of these were minor issues caused by small overlaps between walls and floor slabs or valid penetrations of elevator shafts, mechanical shafts, and stair cores passing through floors. However, several major conflicts required design revisions. The most significant issue was the structural columns in the stairwells. I plan to relocate the staircases within the architectural layout to avoid disrupting the evenly spaced structural grid. Another issue was that the structural cantilever walls were positioned too close to the stairs, which caused many clashes with stair landings, railings, and stringers. Many interior walls overlapped with these structural shaft walls too.

Based on the clash detection results, I will make several architectural adjustments. These include relocating the staircases to eliminate conflicts with structural columns, increasing the clearance between the stairs and cantilever walls, repositioning interior walls to avoid overlap with shaft walls, and refining the curtain wall and balcony layouts around the shaft walls. These changes will improve coordination between the architectural and structural systems while maintaining an efficient structural grid.