Module 6 Template

Link to Student
Submitted For
Module 6 - Load Bearing

Working links to both Arch and Stru models in Forma Data Management.

Architectural Model: https://acc.autodesk.com/docs/files/projects/22ab350f-83cb-4d7e-9708-72b2aed7eafd?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.-Hpkw2MmSXu7OI1DARD-dQ&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3ADqJQP2NhRdCEGDaDSXWQ_w&viewModel=detail&moduleId=folders

Structural Model: https://acc.autodesk.com/docs/files/projects/22ab350f-83cb-4d7e-9708-72b2aed7eafd?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.-Hpkw2MmSXu7OI1DARD-dQ&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3A8GoDhPgfTha8Cm8KRL5Rug&viewModel=detail&moduleId=folders

Working link to your Individual Forma Board

Forma Board Link

PDF sheet set of Structural Plans, 30 by 42 inches (E1 size)

Sobers_UC_Structural_MOD6.pdf4 MiB

Classified clash report with counts.

Clash Grid:

image

Clash Report:

Issue summary-202611070403.pdf160.4 KiB

Design memo of 300 to 400 words: which system and why, where the grid fought your architecture, what you changed in the architectural model.

I chose a reinforced-concrete system to balance the building’s space constraints, rooftop uses, and structural connections. Concrete’s potential for relatively thin floor plates suited the limited floor-to-floor heights established in the architectural model. The occupied rooftop terraces were another major consideration, including the weight of pavers, furniture, and people using these spaces. The concrete should also help reduce sound transmission between residential units and from terraces to the rooms below.

I also considered wood framing over a concrete podium for its potential embodied-carbon savings. However, the changing layouts and setbacks between floors made a system less dependent on stacked bearing walls appealing.The skybridge also influenced my choice, since connecting it to wood-framed upper floors would require additional coordination and potentially separate supports. A concrete frame provided a more consistent approach to supporting the bridge at both ends.

The main conflicts occurred along the exterior and courtyard façades, where columns and beams intersected walls, doors, and windows. These areas need closer coordination to fit the structure into the façade layout. Some columns on the commercial and residential floors were also slightly offset, so I am exploring changes to bring their footprints into better alignment and allow columns to continue between levels. The structural model also highlighted conflicts in the roof layers and helped pinpoint where those assemblies need to be revised.

Most internal spaces worked with the structural layout and could remain as designed. The remaining adjustments mainly involve small lobby and gathering areas along the corridors, where structural elements affect the available space. Within the residential units, the main concern is the typical bathroom layout, which needs minor reorientation to accommodate the structure. These changes are still being coordinated in the architectural model.