Module 6 Template

Link to Student
Submitted For
Module 6 - Load Bearing

Working links to both Arch and Stru models in Forma Data Management.

Architectural: https://acc.autodesk.com/docs/files/projects/a58b5ae1-155b-40ca-a81d-8778ff3e1973?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.eqA1wfYoTEWeyNFcCTwxUw&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3A79boxbJITCa0XjtWAdUMQA&viewModel=detail&moduleId=folders

Structural: https://acc.autodesk.com/docs/files/projects/a58b5ae1-155b-40ca-a81d-8778ff3e1973?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.eqA1wfYoTEWeyNFcCTwxUw&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3Ap11AqA62QCqa8RAC7O8uLA&viewModel=detail&moduleId=folders

Working link to your Individual Forma Board

https://app.autodeskforma.com/board/up_0jwzjum5am/board_18ca2495-df06-495a-b356-390a33095144?x=-39359.38579971934&y=12563.340025289861&w=68067.86286705713&h=36586.47791390752

PDF sheet set of Structural Plans, 30 by 42 inches (E1 size)

Classified clash report with counts.

image

Design memo of 300 to 400 words: which system and why, where the grid fought your architecture, what you changed in the architectural model.

I used a concrete system for the ground floor where the commercial space will be, and then a timber wood system for the residential floors above the ground floor. I wanted to use wood for the majoriuty of the building, as it is the cheapest and lowest carbon option; I used concrete for the ground floor due to its acoustic separation, which I thought was desirable in between stores in the commercial mall. It was difficult to make column grids for this assignment, as the columns would ideally be hidden in the walls. I had to navigate around placing columns in the stairwells, elevator/mechanical shafts, and in the hallways. I also tried my best to avoid placing columns in teh residential units, but that seemed to be impossible and I did have to compromise on some occasions. This all made evenly spacing the column grids, within the rule-of-thumb constraints, a hard task. On each of the grids, I had a few columns that were set at a slightly uneven distance than the spacing carried through the rest of the grid (always within a few inches, however). I also ended up with far more columns than I had anticipated, which will pose a problem with my architectural vision, as not all of these columns can be hidden in walls.

After copying the architectural and structural models into the coordination space, I faced further difficulty. Many of the columns I had placed were in front of windows or balcony doors, which was not visible when I was laying the column grid. Many of my foundation cantilevel walls around the stairwells also conflicted with windows I had drawn in the architectural plan to increase natural light in the stairwells. I also had many clashes that did not appear to be actual issues, such as the wooden joists overlapping with the floor; to my understanding, this is expected because the joists make up the floor.