Module 7 Template

Link to Student
Submitted For
Module 7 - Comfort Zone

Working links to all three models in Forma Data Management and your Forma Board

Please paste your working links to all three models and your Board here…

PDF sheet set at E1 size, 30 by 42 inches

Please paste your PDF sheet set here…

Load summary table: floor total and by zone

Please paste your load summary table here…

Alternatives comparison: your representative unit and your alternative unit, compared by numbers, with your conclusion

Please paste your two alternatives comparison here, what differs between them, and which you choose and why…

Design memo of 300 to 500 words: your strategy and why, what the loads told you about your envelope, where your structure got in the way, and what you left unresolved

HVAC PLAN (11/14/26):

The building is located in California Climate Zone 3, which is predominantly heating-dominated. Using Climate Consultant with ASHRAE Standard 55, the analysis identified internal heat gains (50.2%) and passive solar heating (19.2%) as significant opportunities for thermal comfort, while mechanical heating was recommended for 30.4% of annual hours. For that reason, the design will prioritize insulated walls, double-glazed windows, and a window-to-wall ratio of approximately 30–40% to reduce heat loss while allowing passive solar gains. Given the predominantly east- and west-facing residential facades, selective shading and glazing choices will balance beneficial solar heating with the risk of summer overheating.

The building's stepped geometry naturally groups residential units with potentially different thermal demands, making a distributed HVAC system appropriate. Additionally, limited space along the courtyard-facing façades makes individual outdoor equipment undesirable. Instead, shared mechanical equipment will be located on the available non-occupied rooftops, with vertically aligned mechanical shafts allowing distribution between floors.

Ventilation will be provided by distributed dedicated outdoor air systems (DOAS), supplying fresh air through vertical ducts. Separately, rooftop electric air-to-water heat pumps will provide heating and cooling through water pipes connected to fan coil units in each apartment. Water-based distribution reduces the size of heating and cooling ductwork, helping accommodate the limited ceiling space while leaving room for ventilation ducts. Residents will have individual temperature control and operable windows for natural ventilation when conditions permit. The ground-floor commercial spaces will have a separate HVAC system located on their own floor to accommodate their different uses and operating schedules.

MODELING: