Module 7 - Comfort Zone

Working links to all three models in Forma Data Management and your Forma Board

Architectural Model: https://acc.autodesk.com/docs/files/projects/525df394-a0a6-4919-9afc-7d6f0bb71252?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.efvQHZ8QS-mgD9utRJ5DYQ&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3ActgYaJuvSzabpY92z0M0nw&viewModel=detail&moduleId=folders&viewableGuid=63606546-3800-75ee-d598-0c791de27220

Structural Model: https://acc.autodesk.com/docs/files/projects/525df394-a0a6-4919-9afc-7d6f0bb71252?folderUrn=urn%3Aadsk.wipprod%3Afs.folder%3Aco.-n_Pzs1QTmeBiZotJcFP5g&entityId=urn%3Aadsk.wipprod%3Adm.lineage%3AskvbR0_uSbKtumuox1FAbw&viewModel=detail&moduleId=folders&viewableGuid=7a824d48-ddd3-4812-ca60-a5d22783c52d

Mechanical Model: https://acc.autodesk.com/docs/files/projects/525df394-a0a6-4919-9afc-7d6f0bb71252?folderUrn=urn%3Aadsk.wippr

PDF sheet set at E1 size, 30 by 42 inches

Load summary table: floor total and by zone

Alternatives comparison: your representative unit and your alternative unit, compared by numbers, with your conclusion

Design memo of 300 to 500 words: your strategy and why, what the loads told you about your envelope, where your structure got in the way, and what you left unresolved

Comfort Strategy - Comfort & HVAC Design Breakdown

My comfort strategy for comfort and HVAC design focused on Fremont, CA, which is climate zone 3 (warm-summer Mediterranean climate, mild, wet winters). Based on Climate Consultant, the psychrometric chart shows a strongly heating-dominated thermal profile, with internal heat gain accounting for 50.2% of the load. For cooling demand, I will use a low overall need, at about 3%.

I will be choosing a passive design strategy; for envelope operation, I will organize the floor plan so winter sun penetrates daytime use spaces with specific functions that coincide with solar orientation. For thermal mass, the wood floors will provide enough surface mass to store winter daytime solar gain and summer nighttime cooling. For load reduction, lowering the indoor comfort temp at night will be used to reduce heating energy consumption.

When considering ventilation and indoor environmental quality, a mixed-mode ventilation will be used to adjust to the external environmental conditions. For natural mode, operable windows will utilize natural cross-ventilation during mild outdoor conditions. The mechanical/sealed mode uses insulating blinds, heavy draperies, or operable window shutters to help reduce nighttime heat losses. In the context of heat recovery, there is a need for a fan-powered HRV to ensure indoor air quality while also conserving energy.

The heating equipment used will be a decentralized in-unit ducted heat pump system, and a rooftop-mounted air-source condenser unit array for heat rejection. For metering and control, individual unit sub-metering will be used to track and bill energy use per tenant. The cooling capacity will be sized for a low-hour cooling profile due to Fremont being in Climate Zone 3.

The primary layout for air transportation and delivery distribution will be in-unit soffits routed along the corridor side, serving ceiling supply diffusers. The secondary/alternative layout will be the main branch runs that integrate within the central corridor. My thermal zoning strategy will be a single thermal zone per residential unit controlled by an individual smart thermostat. For corner units, a dual-zone layout split by solar orientation will be used to prevent thermal imbalance caused by solar exposure.