Load summary table: floor total and by zone

Alternatives comparison: your representative unit and your alternative unit, compared by numbers, with your conclusion
My alternative mechanical system design is in room 321. This is the same type of unit as 313 and same size as well. The only thing I changed for this design is where the diffusers are placed. Both units have a fan coil in the same spit that moves 220 CFM. The difference is that in 313, one long duct runs across the unit and in 321, there are more turns in the main duct to reach both diffusers. In 321 the flexible ducts are about 6 ft shorter than in unit 313, but the total amount of duct distance is about the same (around 53 ft). Unit 321 has shorter flexible ducts connecting the diffusers, so this layout may be more ideal.
Design memo of 300 to 500 words: your strategy and why, what the loads told you about your envelope, where your structure got in the way, and what you left unresolved
From the climate consultant, the three main areas to focus on for this design were the internal heat gains, the passive solar direct gain low mass, and the heating. Each apartment has its own fan coil system right near the entry of the unit. In unit 313 and unit 321, I put two supply diffusers and 1 return air diffusers due to the load demand of the apartment. The supply diffusers are connected to the rigid duct through a flexible duct, and the return air diffuser is connected to the fan coil through a flexible duct. By giving each unit their own system, the resident will be able to control their own temperature. I picked the B01-L02 floor plan because this is the one I have been treating as my “typical” floor plan. It is one of the residential floors that has identical floor plans to the 5 floors above it. The loads showed me that the corner units have the most heat loss because they have more exposure to exterior walls. The middle units have less heat loss because they do not have as much exposure to exterior walls. The units fully enclosed in the building, like the common space, have the least amount of heat loss because they are not exposed to exterior walls at all. Each unit only needed about 200-400 CFM. As per the video, the corner units are split into two as they have more exposure to exterior walls. One issue I noticed with my structure is that there is not that much room above the ceiling, and the beams take up some of the space too. One thing that I left unresolved is that Revit split each apartment into 2 units and double counted the occupants, so the cooling numbers may be a little bit too high.