Module 8 Template

Link to Student
Submitted For
Module 8 - Wired and Plumbed
💡

Please enter the following info in the fields above:

  • Link to Student (type the first few letter of your name, then select yourself in the list of linked records)
💡

What to Submit

  1. Working links to all five models in Forma Data Management (architectural, structural, mechanical, plumbing and electrical) and your Individual Forma Board.
  2. PDF sheet set at E1 size, 30 by 42 inches, four sheets: plumbing plan, riser section showing the sanitary fall, power plan, lighting plan.
  3. Your illumination spot check result.
  4. Design memo of 300 to 500 words: where the sanitary riser went and why, what gravity forced you to change, whether your daylighting reduced your lighting load, and what you left unresolved.

Working links to all five models in Forma Data Management (architectural, structural, mechanical, plumbing and electrical) and your Individual Forma Board

Forma board

Architectural model

Structural model

Mechanical model

Plumbing model

Electrical model

PDF sheet set at E1 size, 30 by 42 inches, four sheets: plumbing plan, riser section showing the sanitary fall, power plan, lighting plan

Chen-Building-Plumbing-Week-8.pdf376.7 KiB
Chen-Building-Elec-Week-8.pdf229.4 KiB

Your illumination spot check result

Room type
Model values (lx)
Typical values (lx)
Bedroom
61 (A), 60 (B)
50
Washroom
295 (A), 286 (B)
200
Living room
126
100
Kitchen
228
215

All room types are able to meet the minimum illumination requirements. Adjustments to the washrooms and kitchen needed to be made from the original design to meet the requirements. In particular, the washrooms required significantly more lighting than expected.

Design memo of 300 to 500 words: where the sanitary riser went and why, what gravity forced you to change, whether your daylighting reduced your lighting load, and what you left unresolved

When designing the plumping system, I had to revise the architectural model because none of the walls in the washroom were wide enough to support the 6” pipes. Additionally, not all of my plumbing fixtures were on the same wall, so I decided to have the risers on the wall with the shower and bathtub, and have the pipes extend across the room to connect with the toilet and sink. I chose this wall because it has a shorter length, which means less wall material is required to increase its width.

There were other considerations with the plumbing system. There were a lot of clashes with the structural joists that had to be worked around. For one, some of the pipes had to be run at a lower elevation than what was proposed on the playbook because they would otherwise run into the existing joists. Additionally, the shower drain managed to land on a joist, which can either be resolved by the structural team to move the joist, or the architecture team to move the shower. In the plumbing model, I chose to leave the shower and joist as is, and note the clash for future revisions.

The facade decisions I made did have impacts on the lighting load, but they were minor. The windows in the unit I modelled brought daylight to the bedrooms and living room. However, according to typical illumination requirements, these rooms have the lowest illumination requirements, with 50lx for bedrooms and 100lx for living rooms. In contrast, the high illumination rooms, washrooms and kitchens, were on the other side of the windows, and thus received no benefit from daylight. If I were to redesign the unit, I would place the kitchen on the side of the windows, and try to have one window in each washroom. Instead, I had to workaround the lack of daylight by having a large number of lights in both washrooms and the kitchen, which could be avoided by better unit planning.